The Model 100SB 
                                                  is an instrument with the compact 
                                                  designs for budget-priced starting 
                                                  into the contact  
                                                  angle measuring technique and 
                                                  drop shape analysis, for the 
                                                  software-controlled measurement 
                                                  and  
                                                  analysis of : 
                                                        
                                                    The static and dynamic contact 
                                                    angle according to the Sessile 
                                                    and Captive Drop method as 
                                                    well as the        analysis 
                                                    of the drop shape according 
                                                    to the Pendant Drop method 
                                                          
                                                    The wetting behavior on solid 
                                                    surfaces 
                                                          
                                                    The surface free energy of 
                                                    solids and their components 
                                                          
                                                    The surface and interfacial 
                                                    tension out of the analysis 
                                                    of the drop shape 
                                                     
                                                    The Model 100SB consists of 
                                                    the basic hardware with the 
                                                    following technical features: 
                                                        
                                                    Basic platform with needle 
                                                    holder and syringe support 
                                                          
                                                    Homogeneous LED back lighting 
                                                    electronics with continuously 
                                                    adjustable intensity 
                                                          
                                                    Measuring stage , adjustable 
                                                    in three axis for the accurate 
                                                    sample positioning 
                                                          
                                                    Adjustable tilt optics 
                                                          
                                                    Fixed lens with optional high-performance 
                                                    lens with an integrated continuous 
                                                    fine focus 
                                                          
                                                    High resolution 1280 x 1024 
                                                    USB 2.0 camera; optional 60 
                                                    fps speed camera 
                                                          
                                                    Manual dosing unit with fine 
                                                    1.0 ul adjustable syringe 
                                                          
                                                    Integral X-Y-Z fine adjustable 
                                                    needle holder 
                                                  The Model 100SB Software 
                                                    developed for Windows NT/2000/XP 
                                                    offers by various expansion 
                                                    steps:  
                                                      1. 
                                                    Static and dynamic contact 
                                                    angle measurement according 
                                                    to the Sessile and Captive 
                                                    Drop method 
                                                        2. 
                                                    Sessile Drop method using 
                                                    4 different fitting algorithms 
                                                    : Laplace-Young Fitting, Circle 
                                                    Fitting, Conic         Fitting, Polynomial 
                                                    Fitting (Tangent Fitting) 
                                                     
                                                        3. 
                                                    Surface tension and interfacial 
                                                    tension of a liquid/liquid 
                                                    system can be determined by 
                                                    using the         Pendant Drop (or 
                                                    Rising Bubble) method and/or 
                                                    Captive Bubble method 
                                                        4. 
                                                    Auto baseline detection with 
                                                    manual curved-surface baseline 
                                                    function 
                                                        5. 
                                                    Movie video recording or computation 
                                                    functions with rate of 15 
                                                    fps for dynamic study like 
                                                            absorption, spreading, reaction 
                                                    kinetics, software trigger 
                                                    function with recording and 
                                                    playing speed,         time settings 
                                                    etc. 
                                                        6. 
                                                    Gauge ball, needle or known 
                                                    liquids calibration function 
                                                        7. 
                                                    Result Data Center for storing, 
                                                    managing, analyzing and exporting 
                                                    measuring data by user-defined 
                                                            tasks or drops basis, computation 
                                                    results with display items 
                                                    settings and graph view 
                                                        8. 
                                                    Surface free energy computation 
                                                    with methods Wu, Zisman plot, 
                                                    Owens-Wendt, Fowkes, Extended 
                                                            Fowkes, Acid-Base, Equation 
                                                    of State etc. using chemical 
                                                    substances and test samples 
                                                    database 
                                                        9. 
                                                    Wetting behavior analyzer 
                                                    for building wetting envelopes 
                                                    on all SFE methods 
                                                   
                                                  Technical Data:  
                                                        
                                                    Size of the sample stage: 
                                                    standard 90 x 90 mm, optional 
                                                    specified sample stage 
                                                          
                                                    Maximum sample size (W x L 
                                                    x H): 18 x μ x 9 cm 
                                                          
                                                    Size of the device (L x W 
                                                    x H): 35 x 12 x 35 cm 
                                                          
                                                    Range of contact angle measuring: 
                                                    0~180° ± 0.1°  
                                                          
                                                    Range of surface and interfacial 
                                                    tension: 0.01 ~ 2,000 mN/m 
                                                    ± 0.05 mN/m 
                                                          
                                                    Weight: 6.0 kg   |